Philips North America, LLC: HeartStart MRx Monitor/Defibrillator Model # M3535A - Product Usage: The HeartStart MRx is a lightweight, portable external defibrillator, offering two modes of operation for defibrillation: manual mode and semi-automatic mode (AED). In manual mode, the HeartStart MRx is a full featured manual defibrillator, designed for use by clinicians trained in Advanced Cardiac Life Support (ACLS). Manual operation allows users to select energy levels for external and internal defibrillation. Users may also perform synchronized cardioversion. Non-invasive external pacing is a device option. In AED mode, the HeartStart MRx allows the provider who is trained in Basic Life Support (BLS) to provide defibrillation therapy. The device analyzes a patient s rhythm and advises the user to deliver a shock. Voice prompts guide the user through the defibrillation process by providing instructions and patient information. The voice prompts are reinforced by messages that appear on the display. In both modes of operation, the HeartStart MRx utilizes impedance compensating biphasic truncated exponential therapy waveform. The HeartStart MRx can also be used for ECG monitoring of a patient using 3, 5 or 12 lead cables.

Recall number
Z-2488-2019
Recalling firm
Philips North America, LLC
Product
HeartStart MRx Monitor/Defibrillator Model # M3535A - Product Usage: The HeartStart MRx is a lightweight, portable external defibrillator, offering two modes of operation for defibrillation: manual mode and semi-automatic mode (AED). In manual mode, the HeartStart MRx is a full featured manual defibrillator, designed for use by clinicians trained in Advanced Cardiac Life Support (ACLS). Manual operation allows users to select energy levels for external and internal defibrillation. Users may also perform synchronized cardioversion. Non-invasive external pacing is a device option. In AED mode, the HeartStart MRx allows the provider who is trained in Basic Life Support (BLS) to provide defibrillation therapy. The device analyzes a patient s rhythm and advises the user to deliver a shock. Voice prompts guide the user through the defibrillation process by providing instructions and patient information. The voice prompts are reinforced by messages that appear on the display. In both modes of operation, the HeartStart MRx utilizes impedance compensating biphasic truncated exponential therapy waveform. The HeartStart MRx can also be used for ECG monitoring of a patient using 3, 5 or 12 lead cables.
Status
Terminated
Initiated
2019-07-16
Posted
not on file
Terminated
2022-10-20
Reason
Non-conforming devices are identified, which may not have been included in prior field actions and may not have had a number of corrections applicable to these devices.
Root cause
Other
Action
1. Locate the MRx devices M3535A with the serial numbers US00539461 and US00539462. 2. Remove them from clinical use and quarantine these two devices in a secure location. 3. A Philips representative will contact you to arrange for the removal of the affected HeartStart MRx devices and return them to the factory. If you need further information or support concerning this notification, please contact your local Philips representative or call us at 1-800-722-9377.
Quantity
2 units
Distribution
US Nationwide distribution in the state of MA.
Lot, serial or model codes
Lot/ Serial # US00539461, US00539462
510(k) numbers
K063375
PMA numbers
not on file
Product code
MKJ
Firm FEI
1218950
Firm city
Andover
Firm state
MA
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register