Skip to the content

FDA Medical Device Recalls (openFDA)

X-Laser Llc: X-Laser Laser Light Show projector models Aurora, Caliente Aurora, PSX-400, Mobile Beat Max, Mobile Beat Max MKII, X-Beam, Hawk 500 High-power laser light show projector.

Recall number
Z-2870-2017
Recalling firm
X-Laser Llc
Product
X-Laser Laser Light Show projector models Aurora, Caliente Aurora, PSX-400, Mobile Beat Max, Mobile Beat Max MKII, X-Beam, Hawk 500 High-power laser light show projector.
Status
Terminated
Initiated
2017-07-24
Posted
not on file
Terminated
2024-04-16
Reason
Failure to comply with performance standard requirements (21 CFR 1040.10(f))when operated in the user accessible auto and music modes of operation
Root cause
Device Design
Action
X-Laser LLC will bring into compliance: 1. All purchasers and associated dealers of affected LLS projector models will be notified by mail and email of their failure to comply with the performance standard. The notification will follow the format and include the information required by 21 CFR 1003.21. Those that do not respond within 14 days will be notified a second time. Those not responding to the second attempt will be notified again every 6 months for the next 2 years. Non-responsive dealers will be ineligible for future orders. 2. All affected LLS projectors will be repaired by removing the auto and music modes from the dipswitch accessible settings, after which, these modes will only be accessible through the DMX connection. These actions, including transportation of the LLS projector, will be made free of charge. 3. All LLS projector models that X-Laser receives, regardless of purpose, will be checked for dipswitch accessible auto or music modes and repaired if needed. 4.Corrective actions will be completed within 120 days of receipt of this letter. For further questions please call (866) 702-7768.
Quantity
830
Distribution
US Distribution
Lot, serial or model codes
LLS projectors
510(k) numbers
not on file
PMA numbers
not on file
Product code
REA
Firm FEI
3010087512
Firm city
Laurel
Firm state
MD
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register