Skip to the content

FDA Medical Device Recalls (openFDA)

Becton Dickinson & Co.: BBL" OXACILLIN SCREEN AGAR, catalog #221952, box of 10 plates. Oxacillin Screen Agar (originally named MRSA Screen Agar) was developed for the detection of methicillin-resistant Staphylococcus aureus (MRSA). These strains are resistant to penicillinase-resistant penicillins (PRPs), such as methicillin, oxacillin and nafcillin. Since the method to detect MRSA uses the same inoculum as the Bauer-Kirby antimicrobial disc susceptibility test procedure, the oxacillin screen test may be conveniently performed on isolates at the same time as routine susceptibility testing.

Recall number
Z-2608-2011
Recalling firm
Becton Dickinson & Co.
Product
BBL" OXACILLIN SCREEN AGAR, catalog #221952, box of 10 plates. Oxacillin Screen Agar (originally named MRSA Screen Agar) was developed for the detection of methicillin-resistant Staphylococcus aureus (MRSA). These strains are resistant to penicillinase-resistant penicillins (PRPs), such as methicillin, oxacillin and nafcillin. Since the method to detect MRSA uses the same inoculum as the Bauer-Kirby antimicrobial disc susceptibility test procedure, the oxacillin screen test may be conveniently performed on isolates at the same time as routine susceptibility testing.
Status
Terminated
Initiated
2011-04-20
Posted
2011-06-21
Terminated
2011-08-15
Reason
Oxacillin Screen Agar may not have been produced according to specification and could result in false antibiotic susceptibility test results in patient specimens.
Root cause
Nonconforming Material/Component
Action
BD Diagnostic Systems sent an "URGENT PRODUCT RECALL" letter dated April 2011 to all affected customers. The letter identifies the product, problem and actions to be taken by the customers. The letter instructed customers to discontinue use of the affected lot number and discard any remaining packages. Customers were requested to complete and return an attached response form via fax at 410-316-4258. The letter states that all discarded product will be replaced. Questions concerning the recall process were directed to BD Customer Service Department at 1-800-675-0908.
Quantity
5440 plates
Distribution
Worldwide Distribution--USA (nationwide) and the countries of Canada, Columbia, Jamaica, South Korea, and Taiwan.
Lot, serial or model codes
Lot 1034119 Exp. 2011/05/03
510(k) numbers
["K863821"]
PMA numbers
not on file
Product code
JTZ
Firm FEI
1119779
Firm city
Sparks
Firm state
MD
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register