FDA Medical Device Recalls (openFDA)
Sunrise Medical (US) LLC: Zippie IRIS Wheelchair. model EIZ5A in combination with option code 188M02 - MONO Backrest system with Dynamic Backrest option. Provide mobility to persons limited to a sitting position.
- Recall number
- Z-2466-2015
- Recalling firm
- Sunrise Medical (US) LLC
- Product
- Zippie IRIS Wheelchair. model EIZ5A in combination with option code 188M02 - MONO Backrest system with Dynamic Backrest option. Provide mobility to persons limited to a sitting position.
- Status
- Terminated
- Initiated
- 2015-07-27
- Posted
- 2015-08-26
- Terminated
- 2015-12-10
- Reason
- Quickie IRIS and Zippie IRIS tilt-in-space wheelchairs with MONO Backrest System with Dynamic Backrest may break over time resulting in a fall or injury to occupant.
- Root cause
- Device Design
- Action
- Sunrise Medical sent an Urgent Medical Device Field Correction letter dated July 27, 2015, to all affected dealers. The letter identified the product, the problem, and the action to be taken by the dealer. Dealers were instructed to immediately contact their customers to make arrangements to have the correction made with a replacement kit which will be supplied by Sunrise Medical to each dealer. Each dealer is requested to send back to Sunrise Medical the Acknowledgment and Response Form(s) by fax, email or regular mail once the work is completed. Customers with questions were instructed to contact Sunrise Medical Regulatory Affairs at (888) 208-4901.
- Quantity
- 64 total wheelchairs, both models
- Distribution
- Worldwide Distribution - US (nationwide) and Internationally to Australia, Germany and Canada.
- Lot, serial or model codes
- Model EIZ51, serial number range - ZRS-042132 to ZRS-042157.
- 510(k) numbers
- ["K123975"]
- PMA numbers
- not on file
- Product code
- IOR
- Firm FEI
- 2937137
- Firm city
- Fresno
- Firm state
- CA
- Firm country
- not on file
Where this comes from
- Register
- FDA Medical Device Recalls (openFDA)
- Publisher
- U.S. Food and Drug Administration (openFDA)
- File
- device-recall-0001-of-0001.json.zip
- sha256
- b87518bfe2e8
- Size
- 288210821 bytes
- Published
- 2026-09-28
- Read
- 2026-09-29T08:25:23.626Z
- Source file
- Source file retained · verify
- Refresh due
- 2026-10-06
Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.
Cite as
FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28