Philips North America, LLC: Magnetic Resonance Imaging Diagnostic Device accessory - Product Usage: The chest pneumograph (also referred to as the pneumatic bellows, respiration bellows, or respiration sensor) monitors bellows-derived respiration by detecting abdominal or chest wall motion. The chest pneumograph is an accessory to a MRI patient monitoring system or MRI gating solution. The Chest Pneumograph is indicated for use by healthcare professionals with the Wireless Sp02 (wSp02) Module or Toshiba KSB gating unit when bellows-derived respiration sensing is needed during MRI scans for gating.

Recall number
Z-2245-2020
Recalling firm
Philips North America, LLC
Product
Magnetic Resonance Imaging Diagnostic Device accessory - Product Usage: The chest pneumograph (also referred to as the pneumatic bellows, respiration bellows, or respiration sensor) monitors bellows-derived respiration by detecting abdominal or chest wall motion. The chest pneumograph is an accessory to a MRI patient monitoring system or MRI gating solution. The Chest Pneumograph is indicated for use by healthcare professionals with the Wireless Sp02 (wSp02) Module or Toshiba KSB gating unit when bellows-derived respiration sensing is needed during MRI scans for gating.
Status
Terminated
Initiated
2020-04-13
Posted
not on file
Terminated
2023-04-14
Reason
The labeling of the Philips Chest Pneumograph does not include a statement indicating that the product contains natural rubber latex.
Root cause
Under Investigation by firm
Action
In March of 2020 Philips Healthcare sent out an Urgent Medical Device Corrective Action Notice identifying the problem, under what circumstances it can occur, the actions that should be taken by the customer/user to prevent risks for patients/users, and the actions planned by Philips to correct the problem. PRODUCTS: All Pneumograph, chest, NM, 3160 with part #94023 are affected. ACTIONS TO BE TAKEN: Customers/users are asked to review the Notification letter and share with all members of staff who utilize this product. Customers/Users should also retain a copy with the equipment Instructions for Use. The chest pneumograph can continue to be used for monitoring as directed by a physician. 1.Identify all affected chest pneumographs in your facility using the guidelines provided in the HOW TO IDENTIFY AFFECTED PRODUCTS section above.Do not return any product to Philips. 2. Complete and sign the reply form provided on the last page of this letter. 3. Send the completed and signed reply form to Philips via the contact information located on the form. 4. Upon receipt of the reply form, Philips will send you one kit per chest pneumograph in your possession along with instructions for labeling each chest pneumograph. 5. Upon receipt of the kit, follow the included instructions to label each chest pneumograph in your possession. The label to be added identifies the product as containing latex. ACTIONS PLANNED BY PHILIPS: Upon receipt of the completed and signed reply form, Philips will provide one kit per chest pneumograph in each customers possession for the purposes of labeling each affected chest pneumograph. This kit will be provided free of charge.
Quantity
1075 Units
Distribution
US Nationwide distribution.
Lot, serial or model codes
Every lot distributed since 1996 with Part #94023
510(k) numbers
["K080038"]
PMA numbers
not on file
Product code
MWI
Firm FEI
1218950
Firm city
Andover
Firm state
MA
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register