Becton Dickinson Infusion Therapy Systems, Inc.: BD Cathena Safety IV Catheter BD Multiguard Technology 18 GA x 1.25 IN, REF: 386865; BD Cathena Safety IV Catheter 20GX1.00IN STRAIGHT BC, REF: 386803; BD Cathena Safety IV Catheter BD Multiguard Technology 20 GA x 1.00 IN, 386862
- Recall number
- Z-1808-2025
- Recalling firm
- Becton Dickinson Infusion Therapy Systems, Inc.
- Product
- BD Cathena Safety IV Catheter BD Multiguard Technology 18 GA x 1.25 IN, REF: 386865; BD Cathena Safety IV Catheter 20GX1.00IN STRAIGHT BC, REF: 386803; BD Cathena Safety IV Catheter BD Multiguard Technology 20 GA x 1.00 IN, 386862
- Status
- Open, Classified
- Initiated
- 2025-04-21
- Posted
- 2025-05-21
- Terminated
- not on file
- Reason
- Due to a manufacturing defect IV catheter may have a hole in the septum, which may result in blood leakage from the septum during insertion, which may cause blood exposure or the need for a second IV to be placed - which may result in therapy delay.
- Root cause
- Process control
- Action
- On 4/21/2025, Removal notices were sent (mail/email/fax/phone) to Medical Directors, Risk Managers, Medical Device Safety Officers, Nurse Managers, and distributors were informed of the following: - Routine clinical practice of PPE should protect the clinician from mucocutaneous blood exposure. - If leakage from the septum occurs during insertion, the PIVC should no longer be used. It is recommended the clinician places a new PIVC. In addition, they were asked to do the following: 1) Destroy all unused product subject to the recall following your institution's process for destruction. 2. For indwelling catheters, no further action is needed. 3. If a defective product was previously used on a patient with no issues, no further actions are needed. 4. Share this recall notification with all users within your facility network of the product to ensure they are also aware of this recall. 5. Complete and return Customer Response Form via email to Email: BDRC6@bd.com 6. Distributors were asked to identify all customers within their distribution network that purchased any affected product. Then, Provide a copy of the attached customer letter to all customers to advise them of this field action notification. Questions or complaints can be reported to the North American Regional Complaint Center, 1-844-823-5433 Mon Fri 8:00am and 5:00pm CT or Email: productcomplaints@bd.com
- Quantity
- 262,800
- Distribution
- Worldwide - US Nationwide distribution in the states of IN, AL, CA, FL, TX, NJ, MO, NC, NY, OH, AZ, MN, MA, WA, OK, KS, MS, LA, MD, GA, TN, NM, PA and the country of CA.
- Lot, serial or model codes
- REF/UDI-DI/Lot/Expiration: 386865/0100382903868650/4198480/30-Jun-2027, 386803/0100382903868032/4247809/31-Aug-2027, 386862/0100382903868629/4237744/31-Aug-2027
- 510(k) numbers
- ["K220584"]
- PMA numbers
- not on file
- Product code
- FOZ
- Firm FEI
- 1710034
- Firm city
- Sandy
- Firm state
- UT
- Firm country
- not on file
Where this comes from
- Register
- FDA Medical Device Recalls (openFDA)
- Publisher
- U.S. Food and Drug Administration (openFDA)
- File
- device-recall-0001-of-0001.json.zip
- sha256
- b87518bfe2e8
- Size
- 288210821 bytes
- Published
- 2026-09-28
- Read
- 2026-09-29T08:25:23.626Z
- Source file
- Source file retained · verify
- Refresh due
- 2026-10-06
Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.
Cite as
FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28