FDA Medical Device Recalls (openFDA)
Medtronic Spine LLC, formerly Kyphon Inc: Medtronic brand KyphX HV-R Bone Cement with Kyphon mixer, a polymethyl bone cement kit consisting of a quantity of powder (20 g) and a volume of liquid (10 ml/9 g) mixed in a Kyphon mixer for up to two minutes. Model Number: CO1B; Manufactured by Elmdown LTD, London, England, for Medtronic Spine LLC, Sunnyvale, CA. Product is a medical device used during balloon kyphoplasty to cement structures in fractured vertebral bodies.
- Recall number
- Z-1625-2011
- Recalling firm
- Medtronic Spine LLC, formerly Kyphon Inc
- Product
- Medtronic brand KyphX HV-R Bone Cement with Kyphon mixer, a polymethyl bone cement kit consisting of a quantity of powder (20 g) and a volume of liquid (10 ml/9 g) mixed in a Kyphon mixer for up to two minutes. Model Number: CO1B; Manufactured by Elmdown LTD, London, England, for Medtronic Spine LLC, Sunnyvale, CA. Product is a medical device used during balloon kyphoplasty to cement structures in fractured vertebral bodies.
- Status
- Terminated
- Initiated
- 2009-11-10
- Posted
- 2011-03-11
- Terminated
- 2011-03-11
- Reason
- Product may not reach proper viscosity (dough state) and inconsistency or lack of homogeneity during cement preparation and during delivery period.
- Root cause
- Other
- Action
- The firm, Medtronic Spine LLC, sent an "URGENT DEVICE RECALL NOTICE" dated November 9, 2009 to the customers. The notice described the product, problem and actions to be taken. The customers were instructed to return the affected lots to Medtronic Spine; to not use any of the affected product that they may have received (Medtronic will replace any affected product in their inventory), the customer should contact their Medtronic Spine sales representative or customer service at [866-959-7466 or for geography] for assistance with replacement product, and complete and return the URGENT DEVICE RECALL NOTICE: Action Required form to Medtronic Spine LLC via fax at (408) 543-6192 or mail to: Medtronic Spine LLC, Attn: Recall Coordinator, 1221 Crossman Avenue, Sunnyvale, CA 94089. If you have any questions about this notification, please do not hesitate to contact Sr. Director, Regulatory Affairs via email: pamela.n.segale@medtronic.com or phone at (408) 548-5235.
- Quantity
- not on file
- Distribution
- USA including states of: AL, AR, AZ, CA, CO, DC, FL, GA, IA, IN, KY, MA, MD, MO, MT, NC, NM, NV, NY, OH, PA, SC, TN, TX, UT, VA, WI, and WV; and countries including: Argentina, Austria, Belgium, Brazil, Canada, Chile, Cyprus, Czech Republic, Denmark, Finland, France, Germany, Greece, Honduras, Hong Kong, Hungary, India, Iran, Ireland, Israel, Italy, Ivory Coast, Jordan, Kuwait, Lebanon, Luxembourg, Lybia, Malaysia, Malta, Mexico, Morocco, Netherlands, New Caledonia, Norway, Panama, Philippines, Poland, Portugal, Puerto Rico, Reunion, Romania, Saudi Arabia, Singapore, Slovenia, South Africa, Spain, Sweden, Turkey, United Arab Emirates, United Kingdom and Vietnam.
- Lot, serial or model codes
- Lot Numbers: 0000776598, 0000790377, 0000790380, 0000794905, 0000794997, 0000794998, 0000794999, 0000795000, 0000802774, 0000802775, 0000819410, 0000825149, 0000828632, 0000828633, 0000841918, 0000841919, 0000842869, 0000842871, 0000848666, 0000848670, 0000858673, 0000892106, 000089859, 0000911555, 0000922990, 0000925894, 0000930458, 0000931993, 0000945996, 0000952887, 0000958800, 00009666732, 0000966734, 0000972324, 0000972325, 0000975787, 0000982884, 0000994176, 0001008470, 0001008472, 0001008598, 0001033988, 0001034877, 0001045184, 0001045187, 0001050788, 0001050789, 0001056101, 0001056102, 0001060659, 0001060662, 0001067884, 0001067886, 0001081545, 0001104034, 00841918, 88930458, J6092716, J6100426, J6101208, J6101808, J6103009, J6110310, J6110906, J6112008, J6112712, J6120108, J6121203, J6121902, J6121903, J6121904, J6121905, J6121906, J7010201, J7011107, J7011907, J7012506, J7020624, J7021509, J7022202, J7022702, J7030605, J7031401, J7031506, J7032310, J7032702, J7040213, J7041010, J7041301, J7042109, J7050101, J7050405, J7051107, J7051801, J7052511, J7060205, J7061130, J7062109, J7062708, J7070210, J7070706, J7071602, J7071906, J7072702, J7080702, J7081815, J7081816, J7082816, J7090620, J7091106, J7091208, J7091206, J7100606, J7101704, J7101705, J7110523, J7111216, J7111608, J7112823, J7120314, J7122101, J8010201, J8010402, J8010918, J8010718, J8041401, J8041705, J8042401, J8051203, J8051204, J8052915, J8052916, J8060205, J8060410, J8061208, J8010919, J8012214, J8013005, J8020117, J8020722, J8021910, J8030517, J8030518, J8031202, J8032601, J8040717, J8061209
- 510(k) numbers
- ["K033801","K041584"]
- PMA numbers
- not on file
- Product code
- JDZ
- Firm FEI
- 3004904811
- Firm city
- Sunnyvale
- Firm state
- CA
- Firm country
- not on file
Where this comes from
- Register
- FDA Medical Device Recalls (openFDA)
- Publisher
- U.S. Food and Drug Administration (openFDA)
- File
- device-recall-0001-of-0001.json.zip
- sha256
- b87518bfe2e8
- Size
- 288210821 bytes
- Published
- 2026-09-28
- Read
- 2026-09-29T08:25:23.626Z
- Source file
- Source file retained · verify
- Refresh due
- 2026-10-06
Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.
Cite as
FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28