Medtronic Navigation, Inc.: BioTex Reusable Adapter Kit, Part Number 401-021-1010, packaged non-sterile in a dedicated case for steam sterilization The Adapter Kit is used during surgical procedures as an instrument guide holder that maintains the position of an instrument after they have been aligned by the physician via stereotactic guidance during planning and operation of neurological procedures performed in conjunction with the use of the Medtronic StealthStation Image Guided Workstation System.

Recall number
Z-1234-2016
Recalling firm
Medtronic Navigation, Inc.
Product
BioTex Reusable Adapter Kit, Part Number 401-021-1010, packaged non-sterile in a dedicated case for steam sterilization The Adapter Kit is used during surgical procedures as an instrument guide holder that maintains the position of an instrument after they have been aligned by the physician via stereotactic guidance during planning and operation of neurological procedures performed in conjunction with the use of the Medtronic StealthStation Image Guided Workstation System.
Status
Terminated
Initiated
2016-02-22
Posted
not on file
Terminated
2016-06-15
Reason
Medtronic Navigation is recalling the Biotex Adapter Kit because it was commercially distributed by BioTex without a cleared premarket [510(k)] from FDA.
Root cause
No Marketing Application
Action
The firm, Medtronic, sent an "URGENT Medical Device Recall" letter dated 2/2016 to its consignees. The letter described the product, problem and actions to be taken. The identified consignees will be visited by the assigned Medtronic field representative to explain the need for the field action. The consignees are instructed to locate and remove/secure the kit from use. The Medtronic field representative will assist the consignee with identifying and removing the kit, and complete a Customer Visit record for each consignee they are assigned/visit to document the results of their visit. The consignee is instructed to sign the customer visit form presented by the representative. A copy of this record and a letter explaining the FCA will be left with the consignee. Please contact Medtronic Technical Services at 1-800-595-9709 if you have any questions regarding the subject action or the content of the letter.
Quantity
4
Distribution
US Distribution to states of: FL, NJ, AZ, and NC.
Lot, serial or model codes
The adapter kits are not identified with any lot/code numbers. The BioTex Adapter kits were manufactured between 2008 and 2010.
510(k) numbers
["K003201"]
PMA numbers
not on file
Product code
HAW
Firm FEI
1000517638
Firm city
Louisville
Firm state
CO
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register