Skip to the content

FDA Medical Device Recalls (openFDA)

Stryker Craniomaxillofacial Division: MEDPOR BARRIER Sheets Orbital Floor Implant Product Usage: MEDPOR Implants in block, sheet and pre-formed shapes are intended for non-weight-bearing applications of craniofacial reconstruction/cosmetic surgery and repair of craniofacial trauma. MEDPOR Surgical Implants and MEDPOR BARRIER Implants are intended for the augmentation or restoration of bony contour in the craniofacial skeleton.

Recall number
Z-1091-2015
Recalling firm
Stryker Craniomaxillofacial Division
Product
MEDPOR BARRIER Sheets Orbital Floor Implant Product Usage: MEDPOR Implants in block, sheet and pre-formed shapes are intended for non-weight-bearing applications of craniofacial reconstruction/cosmetic surgery and repair of craniofacial trauma. MEDPOR Surgical Implants and MEDPOR BARRIER Implants are intended for the augmentation or restoration of bony contour in the craniofacial skeleton.
Status
Terminated
Initiated
2014-12-17
Posted
2015-02-11
Terminated
2015-11-06
Reason
Potential for implant deformation, implant mechanical stability too low, loss of barrier adhesion intra-operatively, implant damage, implant cracking off/breaking intra-operatively.
Root cause
Process control
Action
Stryker sent an Urgent Medical Device Recall Notice dated December 23, 2014, to all affected customers with a response form to be completed and returned upon receipt and review. The letter identified the affected product, potential hazards, risk mitigation and the actions to be taken. For questions contact Stryker CMF at 1-800-962-6558, or e-mail at CMF-custserv@stryker.com.
Quantity
1051
Distribution
Worldwide Distribution - US Nationwide in the states of PA, KY, VA, CT, UT, MD, AR, FL, TX, AL, DE, IL, IA, MI, CO, OH, GA, CA, DC, MO, LA, WI, ID, SC, NC, NY, MA, NH, CA, OK, MN, KY, IN, OR, TN and the countries of: Argentina, Australia, Canada, Chile, China, Netherlands, France, Spain, South Korea, Colombia, Switzerland, Singapore, and South Africa.
Lot, serial or model codes
Part Number 9305; Lot Numbers 69698, 77004, 81799, A1310051, A1311008, A1311044, A1312011, A1402023, A1404010
510(k) numbers
["K952677"]
PMA numbers
not on file
Product code
FWP
Firm FEI
3005101424
Firm city
Portage
Firm state
MI
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register