Skip to the content

FDA Medical Device Recalls (openFDA)

Arrow International Inc: The Arrow Edge Hemodialysis Catheterization Set Long-Term Access and NextStep Antegrade Hemodialysis Catheterization Set, Long-Term Access, part numbers: AC-15192-SFX, AC-15232-SFX, AC-15272-SFX, AC-15312-SFX, AC-15422-SFX, CS-15192-SFX, CS-15192-SFXM, CS-15232-SFX, CS-15242-I, CS-15272-SFX, CS-15282-I, CS-15312-SFX, CS-15322-I, CS-15362-I, CS-15422-SFX, CS-15502-SFX, CS-15552-I, CSD-15242-I, CSD-15282-I, and CSD-15322-I. The Arrow Edge Hemodialysis Catheterization Set and NextStep Antegrade Hemodialysis Catheterization Set is indicated for use in attaining long- term vascular access for hemodialysis and apheresis.

Recall number
Z-1007-2015
Recalling firm
Arrow International Inc
Product
The Arrow Edge Hemodialysis Catheterization Set Long-Term Access and NextStep Antegrade Hemodialysis Catheterization Set, Long-Term Access, part numbers: AC-15192-SFX, AC-15232-SFX, AC-15272-SFX, AC-15312-SFX, AC-15422-SFX, CS-15192-SFX, CS-15192-SFXM, CS-15232-SFX, CS-15242-I, CS-15272-SFX, CS-15282-I, CS-15312-SFX, CS-15322-I, CS-15362-I, CS-15422-SFX, CS-15502-SFX, CS-15552-I, CSD-15242-I, CSD-15282-I, and CSD-15322-I. The Arrow Edge Hemodialysis Catheterization Set and NextStep Antegrade Hemodialysis Catheterization Set is indicated for use in attaining long- term vascular access for hemodialysis and apheresis.
Status
Terminated
Initiated
2013-02-04
Posted
2015-01-22
Terminated
2016-10-14
Reason
The tunneling sheath packaged within the kits can crack during placement. If the tunneling sheath cracks, it can cause a delay in treatment for the time it takes to retrieve a replacement kit.
Root cause
Component design/selection
Action
An Urgent Medical Device Recall Notification letter, dated February 4, 2014, was sent to direct consignees that identified the product, problem, and action to be taken. Customers were asked to discontinue use and quarantine affected inventory. The Recall Acknowledgement form should be completed and faxed back to 1-800-343-2935. A customer service representative will contact customers with a Return Goods Authorization (RGA) Number and provide instructions for the return of the product. Customers are asked to contact their local sales representative or Customer Service at 1-800-343-2935 with questions.
Quantity
2,480
Distribution
Worldwide Distribution -- US and Canada.
Lot, serial or model codes
Lot numbers: RF2095946, RF2056557, RF2058764, RF2060829,  RF2084897, RF2084162, RF2071325,RF2060831, RF2083836, RF2096027, RF2107409, RF2108329, RF2119933, RF2060836, RF2060899, RF2083837,  RF2084898, RF2107410, RF2108324, RF2071317, RF2121827, RF2058355,  RF2060414, RF2108326, RF2060811, RF2110441, RF2069798, RF2121821,  RF2069964, RF2122497, RF2110442, RF2058357, RF2119935, RF2108330,  RF2121820, RF2057719, RF2056545, RF2111259, RF2096348.
510(k) numbers
["K111117","K111900"]
PMA numbers
not on file
Product code
MSD
Firm FEI
3015859709
Firm city
Reading
Firm state
PA
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register