Skip to the content

FDA Medical Device Recalls (openFDA)

Cardinal Health: Presource Custom Sterile Surgical and Procedure Kits; surgical trays; Cardinal Health, McGaw Park, IL 60085; The kit catalog numbers listed in the code information section below contain one or more of the following listed components: a) Cool Peri-Pad Self-Adhesive Absorbent Pad with Built-In Cold Pack, component C-CP23, vendor part number CP23; b) Giraffe Disposable Skin Temperature Probe, vendor part number 6600-0873-700;

Recall number
Z-0872-2012
Recalling firm
Cardinal Health
Product
Presource Custom Sterile Surgical and Procedure Kits; surgical trays; Cardinal Health, McGaw Park, IL 60085; The kit catalog numbers listed in the code information section below contain one or more of the following listed components: a) Cool Peri-Pad Self-Adhesive Absorbent Pad with Built-In Cold Pack, component C-CP23, vendor part number CP23; b) Giraffe Disposable Skin Temperature Probe, vendor part number 6600-0873-700;
Status
Terminated
Initiated
2011-12-12
Posted
2012-01-26
Terminated
2016-08-29
Reason
Some of the components contained in the Presource kits are being recalled because Cardinal Health has determined that the component manufacturer(s) does not have all necessary FDA registrations or filings needed for this product.
Root cause
PMA
Action
Cardinal Health issued an URGENT: PRODUCT RECALL letter dated December 12, 2011 to the affected hospital consignees via UPS next day air. The letter informed them that their Presource kits listed in the attached spreadsheet contain various components also listed on the attachment that are being recalled because the component manufacturer(s) do not have all the necessary FDA registrations or filings needed for these components. Enclosed with the letter were recall labels, instructing the user not to use the affected component upon opening the kit, to be affixed to the front side of each affected Presource kit and shipping carton in their inventory. The labels have an ID code which coincides with the code on the component attachment to the letter. The accounts were also requested to complete and fax back to Cardinal the enclosed reply sheet acknowledging receipt of the letter and the number of pack/modules labeled. For component credit, the consignees were instructed to contact Presource Sales Operations at 800-766-0706.
Quantity
7,213 each
Distribution
Nationwide Distribution -- California, Georgia, Illinois, Massachusetts, Michigan, New York, North Carolina, Ohio, Pennsylvania, Tennessee, Texas and Wisconsin.
Lot, serial or model codes
all recent lots of the following kit catalog numbers ICU955327G, ICU955327H, and MAT330041C.
510(k) numbers
not on file
PMA numbers
not on file
Product code
LRP
Firm FEI
3001236905
Firm city
Park
Firm state
IL
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register