Biomet Microfixation, Inc.: The SternaLock Blu Implant Tray includes plates, screws, screw measuring device, and blades. The SternaLock Blu Implant Tray would have been found within the following outer containers: Silver Instrument Tray, with a White rack, and there is no Power Driver warning. Labeled in part: "Manufactured for Biomet Microfixation***Biomet Microfixation 1520 Tradeport Drive Jacksonville, FL 32218 USA www.biometmicrofixation.com***#73-1301***STERNALOCK IMPLANT TRAY***256X 125.5 MM (10.080 x 4.940 ") (LXW)***Polypropylene, Aluminum, Stainless Steel***" A 3" tall container, with blue rubber handles, and a Power Driver warning on the container lid. Labeled in part: "Manufactured for Biomet Microfixation***Biomet Microfixation 1520 Tradeport Drive Jacksonville, FL 32218 USA www.biometmicrofixation.com***#73-1302***STERNALOCK BLU IMPLANT TRAY SEMIMODULAR***256X 125.5 MM (10.080 x 4.940 ") (LXW)Polypropylene, Aluminum, Stainless Steel***" A 5" tall container, with a wide metal latch to secure the lid, and there is no Power Driver warning. Labeled in part: "Manufactured for Biomet Microfixation***Biomet Microfixation 1520 Tradeport Drive Jacksonville, FL 32218 USA www.biometmicrofixation.com***#73-1300***STERNALOCK BLU IMPLANT SEMI MODULAR TRAY***228.6X 128.8MM (9.00 x 5.07 ") (LXW)Polypropylene, Aluminum, Radel***". The Biomet Microfixation SternaLock Blu System is intended for use in the stabilization and fixation of fractures of the anterior chest wall including sternal fixation following sternotomy and sternal reconstructive surgical procedures to aid in the alignment and stabilization of bone. There SternaLock instrument tray has been designed specifically to store the implants for this system.

Recall number
Z-0843-2012
Recalling firm
Biomet Microfixation, Inc.
Product
The SternaLock Blu Implant Tray includes plates, screws, screw measuring device, and blades. The SternaLock Blu Implant Tray would have been found within the following outer containers: Silver Instrument Tray, with a White rack, and there is no Power Driver warning. Labeled in part: "Manufactured for Biomet Microfixation***Biomet Microfixation 1520 Tradeport Drive Jacksonville, FL 32218 USA www.biometmicrofixation.com***#73-1301***STERNALOCK IMPLANT TRAY***256X 125.5 MM (10.080 x 4.940 ") (LXW)***Polypropylene, Aluminum, Stainless Steel***" A 3" tall container, with blue rubber handles, and a Power Driver warning on the container lid. Labeled in part: "Manufactured for Biomet Microfixation***Biomet Microfixation 1520 Tradeport Drive Jacksonville, FL 32218 USA www.biometmicrofixation.com***#73-1302***STERNALOCK BLU IMPLANT TRAY SEMIMODULAR***256X 125.5 MM (10.080 x 4.940 ") (LXW)Polypropylene, Aluminum, Stainless Steel***" A 5" tall container, with a wide metal latch to secure the lid, and there is no Power Driver warning. Labeled in part: "Manufactured for Biomet Microfixation***Biomet Microfixation 1520 Tradeport Drive Jacksonville, FL 32218 USA www.biometmicrofixation.com***#73-1300***STERNALOCK BLU IMPLANT SEMI MODULAR TRAY***228.6X 128.8MM (9.00 x 5.07 ") (LXW)Polypropylene, Aluminum, Radel***". The Biomet Microfixation SternaLock Blu System is intended for use in the stabilization and fixation of fractures of the anterior chest wall including sternal fixation following sternotomy and sternal reconstructive surgical procedures to aid in the alignment and stabilization of bone. There SternaLock instrument tray has been designed specifically to store the implants for this system.
Status
Terminated
Initiated
2011-11-23
Posted
2012-01-24
Terminated
2012-04-03
Reason
Biomet Microfixation, Inc., Jacksonville, FL recalled their SternaLock Blu Implant Tray on 11/23/11, model numbers 73-1300 through 73-1302 due to the possibility of an inaccurate reading on the Screw Measuring Area. If used incorrectly, the screw measuring area inside the SternaLock Blu Implant Tray, could lead to the improper selection of a screw 2mm longer than needed.
Root cause
Device Design
Action
Biomet Microfixation, Inc. sent an "URGENT MEDICAL DEVICE RECALL" letter to all affected customers. The letter identifies the product, problem, and actions to be taken by the customers. The letter provides a "Recommended Technique" to be followed to correct the problem until replacement trays are available. Contact the Quality Improvement Manager at 1-800-874-7711 for questions regarding this notice.
Quantity
109 trays
Distribution
Worldwide Distribution-- USA (nationwide) including the states of AL, AZ, CA, CO, DE, FL, GA, HI, IL, IN, KY, MD, MO, MS, NC, NE, NJ, NY, OK, OR, PA, SC, TN, TX, WA, and WI. and countries of Argentina, Australia, Canada, Denmark, Finland, Germany, South Africa, and Spain.
Lot, serial or model codes
Model Number 73-1300, Lot numbers: 032211, 042911, 100611. Model Number 73-1301, Lot numbers: 249640, 280130, 280131, 312560, 031411. Model Number 73-1302, Lot number: 011411.
510(k) numbers
["K110574"]
PMA numbers
not on file
Product code
HRS
Firm FEI
1032347
Firm city
Jacksonville
Firm state
FL
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register