Skip to the content

FDA Medical Device Recalls (openFDA)

C.R. Bard, Inc., Urological Division: Bard CritiCore Monitor, Software Version 2.1, Catalog number 000002N, C.R. Bard, Inc., Covington, GA 30014. Intended for multiple uses as it is an electronic battery-operated monitor used in conjunction with a single-use disposable urine collection container and/or a temperature sensing Foley catheter

Recall number
Z-0719-2011
Recalling firm
C.R. Bard, Inc., Urological Division
Product
Bard CritiCore Monitor, Software Version 2.1, Catalog number 000002N, C.R. Bard, Inc., Covington, GA 30014. Intended for multiple uses as it is an electronic battery-operated monitor used in conjunction with a single-use disposable urine collection container and/or a temperature sensing Foley catheter
Status
Terminated
Initiated
2010-11-17
Posted
2010-12-21
Terminated
2012-02-02
Reason
Error can occur in the reading of the Present Interval Output (PIO) reading when the device is subjected to bumping or forceful replacement of the fluid container.
Root cause
Other
Action
Consignees were notified by an Urgent: Product Advisory Letter and Medica Device Recall letter on/about November 18, 2010. The letter identified the affected product, stated the reason for recall, the interim precautions, and actions to be taken. The letter requested acknowledgement of the recall and to return the entire affected product. Each consignee that is a distributor was instructed to forward the letter to their consignees to retrieve relevant product from those locations. Affected product received by Bard Medical will be reworked with the software upgrade and place back into distribution. Consignees will either receive a software upgrade on site by a third party or replacement product with the software upgrade. For international distribution, the hospital will be informed of this issue through Bard affiliate and Notified Body Bard Europe and managed according to the requirement. If there are questions or assistance is needed, customers can contact BD at 1-770-784-6969.
Quantity
234 units
Distribution
Worldwide Distribution -- U.S., Netherlands, and Japan.
Lot, serial or model codes
Catalog number 000002N, Serial numbers: DYTA0001, DYTA0002, DYTA0003, DYTA0007, DYTA0008, DYTA0011, DYTA0012, DYTA0015, DYTA0016, DYTA0017, DYTA0018, DYTA0019, DYTA0020, DYTA0021, DYTA0022, DYTA0024, DYTA0025, DYTA0027, DYTA0028, DYTA0029, DYTA0030, DYTA0031, DYTA0032, DYTA0033, DYTA0034, DYTA0036, DYTA0037, DYTA0038, DYTA0039, DYTA0040, DYTA0041, DYTA0042, DYTA0043, DYTA0044, DYTA0045, DYTA0046, DYTA0047, DYTA0049, DYTA0050, DYTA0051, DYTA0052, DYTA0053, DYTA0054, DYTA0056, DYTA0057, DYTA0058, DYTA0059, DYTA0060, DYTB0001, DYTB0003, DYTB0004, DYTB0005, DYTB0009, DYTB0010, DYTB0011, DYTB0012, DYTB0013, DYTB0015, DYTB0016, DYTB0020, DYTB0021, DYTB0022, DYTB0023, DYTB0024, DYTB0025, DYTB0026, DYTB0027, DYTB0029, DYTB0030, DYTB0031, DYTB0033, DYTB0038, DYTC0001, DYTC0004, DYTC0010, DYTC0011, DYTC0016, DYTC0017, DYTC0018, DYTC0019, DYTC0020, DYTC0021, DYTC0022, DYTC0024, DYTC0025, DYTC0026, DYTC0027, DYTC0029, DYTC0030, DYTC0031, DYTC0032, DYTC0033, DYTC0034, DYTC0035, DYTC0036, DYTC0037, DYTC0038, DYTC0039, DYTC0040, DYUC0001, DYUC0002, DYUC0004, DYUC0005, DYUC0009, DYUC0012, DYUC0014, DYUC0015, DYUC0016, DYUC0017, DYUC0018, DYUC0019, DYUC0020, DYUD0001, DYUD0002, DYUD0003, DYUD0004, DYUD0005, DYUD0006, DYUD0007, DYUD0008, DYUD0009, DYUD0011, DYUD0012, DYUD0013, DYUD0014, DYUD0015, DYUD0016, DYUD0017, DYUD0019, DYUD0020, DYUD0021, DYUD0022, DYUD0023, DYUD0026, DYUD0027, DYUD0028, DYUD0029, DYUD0030, DYUD0031, DYUD0033, DYUD0034, DYUD0035, DYUD0036, DYUD0037, DYUD0038, DYUD0039, DYUD0042, DYUD0043, DYUD0045, DYUD0046, DYUD0047, DYUD0048, DYUD0049, DYUD0050, DYUD0052, DYUD0053, DYUD0055, DYUD0057, DYUD0058, DYUD0059, DYUE0002, DYUE0007, DYUE0008, DYUE0011, and DYUE0014.
510(k) numbers
not on file
PMA numbers
not on file
Product code
EXS
Firm FEI
1018233
Firm city
Covington
Firm state
GA
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register