Invacare Corp: Invacare Lynx and Panther Scooters, motorized 3-wheeled vehicles.

Recall number
Z-0574-03
Recalling firm
Invacare Corp
Product
Invacare Lynx and Panther Scooters, motorized 3-wheeled vehicles.
Status
Terminated
Initiated
2003-02-10
Posted
2003-02-25
Terminated
2012-04-12
Reason
A short circuit within the charger harness may cause heat damage to the units with potential for fire.
Root cause
Other
Action
On 3/10/2003, the firm mailed recall letters to all affected dealer accounts. The dealers were asked to contact all customers who have purchased the scooters.
Quantity
5,029 scooters
Distribution
The scooters were shipped to dealerships located nationwide, and to foreign distributors located in Barbados, Argentina, Isreal, and Bermuda.
Lot, serial or model codes
Model Numbers: (Lynx) LX-3, SX-3, SX-3P; (Panther) LX-4, MX-4. Serial Numbers: 99J through 00G.
510(k) numbers
["K010135"]
PMA numbers
not on file
Product code
ITI
Firm FEI
1525712
Firm city
Elyria
Firm state
OH
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register