Skip to the content

FDA Medical Device Recalls (openFDA)

Compass Health Brands (Corporate Office): Voyager Rollator-intended as a mechanical walker Model Number: RLEU10xx (RLEU10BL, RLEU10PK, RLEU10WT) RLEU10BL Voyager Rollator Cobalt Blue UPC: 815067078066; RLEU10PK Voyager Rollator Rose Gold UPC: 815067078073; RLEU10WT Voyager Rollator Ice Palace UPC: 815067078080

Recall number
Z-0510-2022
Recalling firm
Compass Health Brands (Corporate Office)
Product
Voyager Rollator-intended as a mechanical walker Model Number: RLEU10xx (RLEU10BL, RLEU10PK, RLEU10WT) RLEU10BL Voyager Rollator Cobalt Blue UPC: 815067078066; RLEU10PK Voyager Rollator Rose Gold UPC: 815067078073; RLEU10WT Voyager Rollator Ice Palace UPC: 815067078080
Status
Open, Classified
Initiated
2022-01-10
Posted
not on file
Terminated
not on file
Reason
Wheel spoke may crack causing the wheel to separate from the axle may result in patient injuries, including bruising and lacerations requiring stitches.
Root cause
Device Design
Action
Compass Health issued Urgent Medical Device recall letter dated January 2022 on 1/11/22 issued to Distributors and Customers via email or hard copy letter. Firm posted recall to their website: https://compasshealthbrands.com/product-recall . Letter states reason for recall, health risk and action to take: Users: Users should stop using the subject products and contact Compass Health Brands. REQUIRED ACTION: 1. The Voyager Rollator casters and axles require replacement. 2. Contact Compass Health Brands at (800) 947 1728 to order replacement kits, P/N Voyager Kit. This kit contains all the parts necessary to complete replacement of the Voyager Rollator casters and axles. 3. A Voyager Caster Installment Guide will be sent as part of the Field Action Kit P/N Voyager Kit and are posted on the Compass Health Brands website. No special certification is required. 4. Complete and return the attached Consumer Field Correction Response Form to Compass Health Brands within fifteen (15) days of receipt of this field correction notification confirming your acknowledgement. Send completed form to Compass Health Brands via email at recall@compasshealthbrands.com. Complete and return this form even if you do not have affected product on hand. 5. Field correction repairs must be completed on affected units before further use of the unit. Distributors: The manufacturer has changed the wheel spoke design to increase the spoke thickness and strength. The manufacturer will supply replacement wheels with the improvement. The improved wheels will be made available to users to replace the existing wheels on the product. 1. Ensure all affected personnel are fully informed of this notice. 2. Forward this notice to your Regulatory Compliance Manager, Purchasing Manager, Customer Service Manager and Field Technicians. 3. The Voyager Rollator casters and axles require replacement. 4. Dealers/distributors or end users should contact Compass Health Brands at (800) 947-1728 and to order replacem
Quantity
3734 units
Distribution
Nationwide
Lot, serial or model codes
Lot/Serial # RM2005000001-RM21004005000 (May 2020 through April 2021 manufacture dates)
510(k) numbers
not on file
PMA numbers
not on file
Product code
ITJ
Firm FEI
3012316249
Firm city
Middleburg Heights
Firm state
OH
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register