GE Healthcare, LLC: Multi Absorber Original, Disposable M1173310 Multi Absorber Original, Disposable, package of 6 pcs, GE Healthcare Finland Oy Made in US Rx Only The GE Healthcare Multi Absorber Original, Disposable is a disposable product intended for use with the GE Healthcare Advanced Breathing System (later ABS), the GE Healthcare EZchange manifold, the GE Healthcare Compact Block, and the GE Healthcare Compact Block II (later Compact Block). The Multi Absorber should only be used with air, oxygen, nitrous oxide, halothane, enflurane, isoflurane, desflurane and sevoflurane. The device is intended to be used under constant attention of qualified professional healthcare personnel.

Recall number
Z-0472-2014
Recalling firm
GE Healthcare, LLC
Product
Multi Absorber Original, Disposable M1173310 Multi Absorber Original, Disposable, package of 6 pcs, GE Healthcare Finland Oy Made in US Rx Only The GE Healthcare Multi Absorber Original, Disposable is a disposable product intended for use with the GE Healthcare Advanced Breathing System (later ABS), the GE Healthcare EZchange manifold, the GE Healthcare Compact Block, and the GE Healthcare Compact Block II (later Compact Block). The Multi Absorber should only be used with air, oxygen, nitrous oxide, halothane, enflurane, isoflurane, desflurane and sevoflurane. The device is intended to be used under constant attention of qualified professional healthcare personnel.
Status
Terminated
Initiated
2013-09-19
Posted
2013-12-13
Terminated
2015-03-10
Reason
GE Healthcare has recently become aware of a potential safety issue due to air leakage associated with the CO2 Multi Absorber.
Root cause
Device Design
Action
GE issued an Urgent Medical Device Correction letter dated September 19, 2013, to all affected customers via Fed Ex overnight mail. The letter identified the product, the problem, and the action to be taken by the customer. Customers were instructed to not use the affected product, isolate all affected product and return the attached form via fax to 800-535-7923. Once the information is received, customers would be contacted with an RMA and replacement information. If product was distributed further the notice should be forwarded to those customers. For questions customers should call 1-800-345-2700, option 2 followed by ooption 2. For foreign customers 1-800-932-0760, option 2. For questions regarding this recall call 262-513-4122. GE issued a press release on 12/30/2013.
Quantity
US: 59,721 boxes, 358,326 canisters; OUS: 3,724 boxes, 22,344 canisters
Distribution
Worldwide Distribution - USA (nationwide) Puerto Rico and Internationally to Canada, Costa Rica, Mexico, and Venezuela.
Lot, serial or model codes
product number M1173310 containing lot numbers 12001 through 13031.
510(k) numbers
not on file
PMA numbers
not on file
Product code
BSF
Firm FEI
2126677
Firm city
Waukesha
Firm state
WI
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register