Cardiac Assist, Inc: SHIP KIT, PROCEDURE KIT, PROTEKDUO LS - DL31 for temporary Cardiopulmonary bypass. Including the following components: a) 31 Fr ProtekDuo Veno-Venous Cannula Set b) LifeSPARC Pump c) 14Fr to 26 Fr Dilator Set d) TandemHeart Wrap. Kit Number: 5820-3118 Intended use is applicable to the intended use of specific devices included in the kit.

Recall number
Z-0311-2022
Recalling firm
Cardiac Assist, Inc
Product
SHIP KIT, PROCEDURE KIT, PROTEKDUO LS - DL31 for temporary Cardiopulmonary bypass. Including the following components: a) 31 Fr ProtekDuo Veno-Venous Cannula Set b) LifeSPARC Pump c) 14Fr to 26 Fr Dilator Set d) TandemHeart Wrap. Kit Number: 5820-3118 Intended use is applicable to the intended use of specific devices included in the kit.
Status
Open, Classified
Initiated
2021-10-14
Posted
not on file
Terminated
not on file
Reason
Top label of the outer package of the collection kit Item 5820-3118 showed expiration date of 2022/05/01 (correct expiration date) while side label showed expiration date of 2021/05/01 (incorrect expiration date)
Root cause
Error in labeling
Action
LiNova issued an "URGENT MEDICAL DEVICE REMOVAL" letter (FA-CP-PIT-2021-003) dated October 13th, 2021 via e-mail on 14 October 2021. Letter states reason for recall, health risk and action to take: TandemLife recommends using the device as labelled and dispose the outer packaging. TandemLife kindly requests your execution of the following actions: 1. Using attached Response Form in Attachment 1 of this letter, please: - If you have already discarded of outer packaging prior to the receipt of this letter, please proceed to step 2 - Check your inventory for the presence of potentially affected kit contained within your ordered kit as per Table provided in Attachment 1; - Please dispose of the outer packaging of your impacted product upon notification of this letter. - Please use your devices as labelled on the device level labeling. 2. Return the attached Response Form in Attachment 1 by email to LivaNova.FSCA@livanova.com to confirm appropriate corrective actions have been executed. Please return the Response Form even if each potentially affected device listed in Attachment 1 has already been used. For questions regarding this Medical Device Removal, please contact your TandemLife representative, or TandemLife Customer Quality at LivaNova.FSCA@livanova.com.
Quantity
7 units
Distribution
US Distribution to states of: DC, MA, SC, and VA.
Lot, serial or model codes
Serial Numbers: 872170, 872171, 872172, 872173, 872182, 872183, 872184. UDI: 01)00814112020791(17)220 501(22)220511(21) 872170; (01)00814112020791(17)220 501(22)220511(21) 872171; (01)00814112020791(17)220 501(22)220511(21) 872172; (01)00814112020791(17)220 501(22)220511(21) 872173; (01)00814112020791(17)220 501(22)220511(21) 872182; (01)00814112020791(17)220 501(22)220511(21) 872183; 01)00814112020791(17)220 501(22)220511(21) 872184
510(k) numbers
["K160257"]
PMA numbers
not on file
Product code
DWF
Firm FEI
3002228812
Firm city
Pittsburgh
Firm state
PA
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register