Philips Healthcare Informatics, Inc.: Philips brand IntelliSpace PACS 4.4, Image Management System; The system is a software package used with general purpose computing hardware to acquire, store, distribute, process and display images and associated data throughout a clinical environment. Product is manufactured and distributed by Philips Healthcare Informatics, Inc. Foster City, CA IntelliSpace PACS are image management systems intended to be used by trained professionals, including but not limited to physicians, nurses and medical technicians. The system is a software package used with general purpose computing hardware to acquire, store, distribute, process and display images and associated data throughout a clinical environment. The software performs digital image processing, measurement, communication and storage. iSite supports receiving, sending, printing, storing and displaying studies received from the following modality types via DICOM: CT, MR, NM, US, XA, PET, DX, DR, RE, RT, MG, SC, VL, as well as hospital/radiology information systems.

Recall number
Z-0269-2014
Recalling firm
Philips Healthcare Informatics, Inc.
Product
Philips brand IntelliSpace PACS 4.4, Image Management System; The system is a software package used with general purpose computing hardware to acquire, store, distribute, process and display images and associated data throughout a clinical environment. Product is manufactured and distributed by Philips Healthcare Informatics, Inc. Foster City, CA IntelliSpace PACS are image management systems intended to be used by trained professionals, including but not limited to physicians, nurses and medical technicians. The system is a software package used with general purpose computing hardware to acquire, store, distribute, process and display images and associated data throughout a clinical environment. The software performs digital image processing, measurement, communication and storage. iSite supports receiving, sending, printing, storing and displaying studies received from the following modality types via DICOM: CT, MR, NM, US, XA, PET, DX, DR, RE, RT, MG, SC, VL, as well as hospital/radiology information systems.
Status
Terminated
Initiated
2013-10-14
Posted
2013-11-13
Terminated
2014-06-11
Reason
Philips Healthcare became aware of a software problem with the IntelliSpace PACS system, in that a timing issue has been identified that may result in a condition where the device does not store additional images received before processing is complete. The missing images may contain pathology which may result in a different diagnosis if they had been available at time of interpretation.
Root cause
Software in the Use Environment
Action
Philips sent an Urgent Field Safety Notice dated October 14, 2013, to all affected customers. The letter identified the product, problem, and actions to be taken by the customers. Please review the following with all radiology technicians who use lntelliSpace BY CUSTOMER/USER PACS: " Assure you and your colleagues are aware of the problem. " Verify that all images sent for each study are present on the iVault before the images are purged from the modality. o Use the image count from the lower right corner of the thumbnails as seen in Enterprise only. Single images (such as CR, DX and MG) show no image count, so the user should count those thumbnails without image counts as one. Add all the numbers up to come up with the total number of viewable images, stored to lntelliSpace. " Compare number of images sent from the modality and those sent from other 3rd party source to image count in IntelliSpace PACS. " If the image count on the modality or 3 party source indicates there are more images to the study than are present on the iVault, the study should be resent from the modality and/or 3 party source. " Resending the studies will typically correct the problem but the technician should again verify the image count is correct. If you need any further information or support concerning this issue, please INFORMATION AND contact your Philips representative or contact Care at isitecare@philips.com. Please call (650) 293-2300 for further questions.
Quantity
71 units
Distribution
Worldwide Distribution - USA (nationwide) and country: Canada.
Lot, serial or model codes
All units of these IntelliSpace PACS.
510(k) numbers
not on file
PMA numbers
not on file
Product code
LLZ
Firm FEI
3002971142
Firm city
Foster City
Firm state
CA
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register