C P Medical Inc.: Product is a synthetic absorbable suture with needle and labeled as sterile. The product is sealed inside an inner foil pouch with an outside Tyvek pouch. The outer sterile barrier seal is intact. The product is boxed and shrink wrapped for protection against contamination. The product is a Violet, monofilament synthetic absorbable suture with needle, size 3/0 (2.0 Metric), NFS-2 Needle (Product code 398A-Polyglycolic Acid) or size 2/0 (3.0 Metric) NFS-1 Needle. (Product code 453A-Polyglycolic Acid). Product is labeled in part: "***NFS-1***CUTTING***Coated POLYGLYCOLIC ACID Violet (PGA) Braided Absorbable Suture STERILE***Manufacturer CP Medical***". Intended for use in general soft tissue approximation and/or ligation including use in pediatric cardiovascular tissue where growth is expected to occur, and ophthalmic surgery. The suture is not recommended for adult cardiac tissue, microsurgery or neural tissue. The absorbable sutures are useful where extended wound support is desirable.

Recall number
Z-0260-2012
Recalling firm
C P Medical Inc.
Product
Product is a synthetic absorbable suture with needle and labeled as sterile. The product is sealed inside an inner foil pouch with an outside Tyvek pouch. The outer sterile barrier seal is intact. The product is boxed and shrink wrapped for protection against contamination. The product is a Violet, monofilament synthetic absorbable suture with needle, size 3/0 (2.0 Metric), NFS-2 Needle (Product code 398A-Polyglycolic Acid) or size 2/0 (3.0 Metric) NFS-1 Needle. (Product code 453A-Polyglycolic Acid). Product is labeled in part: "***NFS-1***CUTTING***Coated POLYGLYCOLIC ACID Violet (PGA) Braided Absorbable Suture STERILE***Manufacturer CP Medical***". Intended for use in general soft tissue approximation and/or ligation including use in pediatric cardiovascular tissue where growth is expected to occur, and ophthalmic surgery. The suture is not recommended for adult cardiac tissue, microsurgery or neural tissue. The absorbable sutures are useful where extended wound support is desirable.
Status
Terminated
Initiated
2009-01-02
Posted
2011-11-19
Terminated
2011-12-13
Reason
The seal integrity of the outer product pouch may be compromised due to partial delamination of the two layers that make up part of the pouch.
Root cause
Nonconforming Material/Component
Action
CP Medical, Inc. sent a "RECALL NOTICE" letter dated January 5, 2009 to all affected customers.The letter describes the product, problem, and the actions to be taken by the customers. Customers are instructed to identify affected product and to return the product to the firm. Customers should call 1-503-232-1555 for a return goods authorization number and shipping account number. Contact your customer service representative at 1-800-950-2763 for questions concerning this recall.
Quantity
13632 sutures
Distribution
Nationwide Distribution
Lot, serial or model codes
398A and 453A
510(k) numbers
["K002190"]
PMA numbers
not on file
Product code
GAM
Firm FEI
3002609049
Firm city
Portland
Firm state
OR
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register