Baxter Healthcare Corp.: Baxter Clearlink Intravenous (IV) Delivery System; the system consists of solution sets, extension sets and blood sets that have a luer activated valve for IV access, which allows the administration of medications/solutions with a needleless luer syringe; Baxter Healthcare Corporation, Deerfield, IL 60015 USA

Recall number
Z-0193-05
Recalling firm
Baxter Healthcare Corp.
Product
Baxter Clearlink Intravenous (IV) Delivery System; the system consists of solution sets, extension sets and blood sets that have a luer activated valve for IV access, which allows the administration of medications/solutions with a needleless luer syringe; Baxter Healthcare Corporation, Deerfield, IL 60015 USA
Status
Terminated
Initiated
2004-04-28
Posted
2004-11-16
Terminated
2007-02-08
Reason
Inadequate directions for use may have contributed to an increase in infection rates at a small number of customers beginning use of the Clearlink needleless device.
Root cause
Other
Action
An Urgent Device Correction letter and reply form dated 4/28/04 were sent to all U.S. Clearlink customers, informing them of the reports of increased infection rates abd describing the revision of the product labeling with additional statements that relate to product usage and reinforcement of standard clinical practices and proper aseptic technique. The revised labeling statements are as follows: * Ensure clamp is open. Swab Luer activated surface with preferred antiseptic prior to first use and before every subsequent connection. * Don not swab Luer activated surface when clamp is closed or valve is recessed. Ineffective swabbibg may result. Replace if valve remains recessed. * Flush Luer activated valve after blood infusion/sampling. If valve cannot be cleared of blood, replace immediately. * Luer lock vacutainer holders, syringes and accessories are recommended for blood sampling. If blood remains on valve surface after sampling, swab surface. * If intermittently disconnecting set from Luer activated valve, immediately cover male Luer with a sterile replacement protector.
Quantity
29,425,708 sets
Distribution
Nationwide, and internationally through Baxter subsidiaries to Macedonia, Nigeria, Saudi Arabia, South Africa, Ireland, Italy, Denmark, Germany, the Netherlands, Hong Kong, Indonesia, Singapore, Spain, Belgium, Norway, United Kingdom, France and Luxembourg.
Lot, serial or model codes
all lots of product code 2N8399, 1C8678, 1C8680, 1C8683, 1C8684, 1C8687, 1C8693, 1C8702, 1C8704, 1C8705, 1C8706, 1C8707, 1C8712, 1C8722, 1C8723, 1C8727, 2C0168, 2C6254, 2C6255, 2C6256, 2C7461, 2C7462, 2C8401, 2C8402, 2C8419, 2C8425, 2C8428, 2C8515, 2C8519, 2C8537, 2C8541, 2C8546, 2C8548, 2C8571, 2C8593, 2C8606, 2C8607, 2C8610, 2C8612, 2C8632, 2C8634, 2C8671, 2C8700, 2C8720, 2C8750, 2C8751, 2C8819, 2C8851, 2C8857, 2C8858, 2C8860, 2C8862, 2C8864, 2C8865, 2C8875, 2C8891, 2C8895, 2C8920, 2C8921, 2C8930, 2C8931, 2H7462, 2H7463, 2H8401, 2H8480, 2H8486, 2H8519, 2H8603, 2H8720, 2H8750, 2H8819, 2H8860, 2H8862, 2H8864, 2H8865, 2N8300, 2N8334, 2N8335, 2N8341, 2N8371, 2N8373, 2N8374, 2N8377, 2N8378, 2N9204K, 2N9205K, 3C0122, 3C0134, 3C0139, 3C0143, 3C0148, 3C0150, 3C0151, 3C0157, 3C0158, 3C0159, 3C0160, 3C0162, 3C0165, 4C8714, 4C8723, 4H8723
510(k) numbers
["K832284","K981792","K984381","K993120","K003225"]
PMA numbers
not on file
Product code
FPA
Firm FEI
1416980
Firm city
Round Lake
Firm state
IL
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register