FDA Medical Device Recalls (openFDA)

Biomet Microfixation, Inc.: 2.0/1.0 4 hole long plate (titanium plate ).Lot 120150. Product labeling reads: (1. ) REF: 01-9205, Lot 999999, " 2.0MM" SYSTEM PLATE 4 HOLE PLATE, STRAIGHT, LONG. (2.) QTY 00001, CE 0086, *** NON-STERILE PRODUCT***, 1.0 MM TITANIUM, BIOMET MICROFIXATION, 1520 TRADEPORT DRIVE, JACKSONVILLE, FL 32218 USA, www.biometmicrofixation.com. (3.) #01-9205, LOT 999999, QTY 00001, 4 HOLE PLATE, STRAIGHT, LONG, 1.0 MM, CE 0086

Recall number
Z-0108-2011
Recalling firm
Biomet Microfixation, Inc.
Product
2.0/1.0 4 hole long plate (titanium plate ).Lot 120150. Product labeling reads: (1. ) REF: 01-9205, Lot 999999, " 2.0MM" SYSTEM PLATE 4 HOLE PLATE, STRAIGHT, LONG. (2.) QTY 00001, CE 0086, *** NON-STERILE PRODUCT***, 1.0 MM TITANIUM, BIOMET MICROFIXATION, 1520 TRADEPORT DRIVE, JACKSONVILLE, FL 32218 USA, www.biometmicrofixation.com. (3.) #01-9205, LOT 999999, QTY 00001, 4 HOLE PLATE, STRAIGHT, LONG, 1.0 MM, CE 0086
Status
Terminated
Initiated
2010-08-31
Posted
2010-10-20
Terminated
2010-11-19
Reason
Mislabeled size: The 2.0/1.0 4 hole long plate, Lot 120150 is labeled as 01-9205 (2.0/1.0 4 Hole Long Plate), however, the package contains a 01-9204 (2.0/1.0 4 Hole Regular Plate).
Root cause
Other
Action
Biomet Microfixation sent URGENT MEDICAL DEVICE RECALL NOTICES dated August 31, 2010 to its customers and distributors, identifying the affected product and actions to be taken by customers. Customers were requested to check their inventory for product and return any affected product to Biomet Microfixation. Customer questions or concerns should be directed to Laura Sabo, VP Global QA/RA at 904-741-4500.
Quantity
56
Distribution
Worldwide Distribution: USA including states of Hawaii and Kansas, and the countries of Australia, Denmark, Italy, Jordan, and South Africa.
Lot, serial or model codes
Lot 120150.
510(k) numbers
["K854886"]
PMA numbers
not on file
Product code
JEY
Firm FEI
1032347
Firm city
Jacksonville
Firm state
FL
Firm country
not on file

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register