Skip to the content

FDA Medical Device Recalls (openFDA)

Leonhard Lang Medizintechnik GmbH: Skintact Electrodes for Defibrillation, DF29N. Product Usage: Multifunction electrode for external defibrillation, pacing, cardioversion, and monitoring. The device is non-sterile and for single use only.

Recall number
Z-0004-2017
Recalling firm
Leonhard Lang Medizintechnik GmbH
Product
Skintact Electrodes for Defibrillation, DF29N. Product Usage: Multifunction electrode for external defibrillation, pacing, cardioversion, and monitoring. The device is non-sterile and for single use only.
Status
Terminated
Initiated
2016-09-01
Posted
2016-10-14
Terminated
2019-03-26
Reason
There is a risk that defibrillation electrodes model DF29N will be connected with the defibrillator Welch Allyn AED 10 only with delay or not at all. This may cause a situation in which a patient, who is in a life threatening condition and requires a defibrillation shock, cannot be treated in good time.
Root cause
Device Design
Action
Consignees was sent via e-mail a Leonhard Lang "Important Safety Notice" dated September 1, 2016. The letter described the product being recalled, Description of the defect, Actions and time frame of the recall, & Compensation for the recalled electrodes. Advised consignees to inform all users within their organizations of the recall; and, secure and destroy the unused electrodes in their inventory. Confirmation of destruction can be done by completing and returning the "Confirmation of Destruction / Consumption" form by October 14, 2016. If the product was further distributed, they were to forward a copy of the Safety Notice. For questions contact sales staff.
Quantity
11,110 ( US 8,040; OUS 3,070)
Distribution
Worldwide Distribution - US, to the state of Florida; and, the countries of South Africa, Germany, Slovenia, France, United Arab Emirates, Great Britain, Italy, Israel, Serbia, Thailand, Thailand, South Africa, Lebanon, and Poland.
Lot, serial or model codes
US: 60602-0774; 60502-0779; 60308-0771; 60114-0773; 51023-0775; 50904-0777; 50403-0778; 50130-0777; 41023-0771; 41008-0778; 40730-0778; 40618-0778; and, 40130-0776. Outside US: 60725-0774; 60620-0776; 60602-0774; 60502-0779; 60308-0771; 60114-0773; 51023-0775; 50904-0777; 50403-0778; 40827-0777; 40730-0778; 40618-0778; and, 40130-0776.
510(k) numbers
["K142803"]
PMA numbers
not on file
Product code
MKJ
Firm FEI
6736
Firm city
Innsbruck
Firm state
not on file
Firm country
Austria

Where this comes from

Register
FDA Medical Device Recalls (openFDA)
Publisher
U.S. Food and Drug Administration (openFDA)
File
device-recall-0001-of-0001.json.zip
sha256
b87518bfe2e8
Size
288210821 bytes
Published
2026-09-28
Read
2026-09-29T08:25:23.626Z
Source file
Source file retained · verify
Refresh due
2026-10-06

Unless otherwise noted, the content, data, documentation, code, and related materials on openFDA is public domain and made available with a Creative Commons CC0 1.0 Universal dedication.

Cite as

FDA Medical Device Recalls (openFDA) (U.S. Food and Drug Administration (openFDA)), device-recall-0001-of-0001.json.zip, sha256 b87518bfe2e8, published 2026-09-28

Search this register